Access control is only as reliable as its installation. The Paxton PaxLock Pro2 Although technically reliable, the installation of these products places clear requirements on the door, lock box and surrounding conditions. By checking these points before installation, you can prevent operational problems and significantly extend the system’s lifespan. The GRAEF Group undertakes the complete installation – from the initial survey to the final functional check – for commercial properties throughout Germany.
What needs to be checked before assembly
Before a PaxLock Pro2 is installed on a door, the door, frame, and lock box must be carefully inspected. The fitting only works reliably over the long term if the environment is suitable. Problems that are overlooked during installation often become noticeable only after weeks of operation – through increased effort when opening, premature battery consumption, or communication disruptions in the connected operation.
Requirements for the lock box
PaxLock Pro2 is designed for lock boxes according to the European DIN profile (DIN 18251-1) and the Scandinavian profile. The lock box must have a pin dimension of at least 55 mm, and the locking return must not exceed 45 degrees. It is expressly recommended to use a lock box with a non-return cylinder function, so that in the rare event of a device failure, access is still possible.
Door gap, stopper and lock
The distance between the door edge and the frame should not exceed 3 mm, so that a safety catch present on the lock housing can function properly. The door stop should not exceed 15 mm. Where a fully open door can hit against a wall, a door stopper must be provided to avoid damage to the fitting. If a door closer is present, it must be adjusted so that the door closes without slamming and opens without excessive effort.
- Lock box certified according to DIN 18251-1, bore size ≥55 mm
- Maximum grip rotation ≤45 degrees
- Door width 35–62 mm
- Door gap between edge and frame ≤3 mm
- Door strike ≤15 mm
- Adjust the door closer for easy closing
- Door stopper recommended in case of danger of impact

Special installation situations
Metal doors
PaxLock Pro2 can be mounted on metal doors when the width and lock box meet the specifications. It is important to note that a metal door can reduce the range of the radio in online operation. In such cases, the Net2 Air Bridge or Paxton10 Wireless Connector must be positioned well within the specified 15-meter range. For highly shielded metal doors, standalone operation may be the more reliable choice.
Fireproof doors
PaxLock Pro2 is certified according to EN 1634-1 and approved for wood fire protection doors of classes FD30 and FD60. All used lock boxes must have an equivalent fire protection certification. Distance pieces must be used in accordance with the manufacturer’s recommendations.
Emergency exits according to EN179
PaxLock Pro2 is certified according to EN179:2008 and is therefore suitable for emergency exits in areas where a panic situation is not expected. For use in accordance with the standard, the separate EN179 kit (article number 901-015) is required. Without this accessory, the system does not meet the EN179 requirements.
Upgrade from PaxLock Pro to PaxLock Pro2
Those who already have PaxLock Pro can upgrade to PaxLock Pro2 without having to replace the entire door installation. The process follows a structured sequence: First, the existing hardware, including the square rod and T-nut, is properly disassembled. Next, the existing lock box is inspected for suitability – condition, function, and certification according to DIN 18251-1 are crucial in this process. Only a flawless lock box without friction or wear is suitable for continued operation.
Using the supplied drill template, existing holes are checked and new holes, such as for the rotation-proof pin, are marked. Subsequently, PaxLock Pro2 is installed and, during commissioning, checked for correct latch retraction, smooth operation, and proper door closing.
Visually unavoidable drill holes from the previous model can be covered with matching covers that are available in various designs for Euro and Scandinavian profiles. These covers are purely for aesthetic purposes – they do not affect the fire resistance of the door.
Commissioning and status display
After assembly, the PaxLock Pro2 is initially in the unlocked state, allowing immediate verification that the latch retracts fully, the door opens smoothly, and the latch returns fully after releasing the handle. The device reports its status via LED signals and beeps: green light indicates granted access, red signal indicates denial. Additional status messages include low battery level, active privacy mode, and ongoing BLE communication.
The GRAEF Group plans and installs Access control systems Based on Paxton PaxLock Pro2 for companies of different sizes – nationwide. The consultation begins with an on-site assessment to fully evaluate the door condition, lock box, and usage requirements before installation. More information about Planning and consulting Our team can be found on our website.